Product Code:

HIB-EN-218E-518V-ML42-MQ18-MV08

Categories:

Capacity:

217.7

kWh

Voltage:

518 V

Dimensions (LxWxH):

Dry Weight (Aluminium):

1151 kg

Pack General Properties

Parameter
Value

Pack Capacity

217.7 kWh

Pack Capacity Derated¹

208.6 kWh

Usable Capacity (for>4000cycles)

208.6

Max Charge Current [A]²

500

Continuous Charge Current²

300 A

Continuous Discharge Current²

155.4 kW

Max Discharge Current²

259 kW

Pack Configuration

8S 84P

No. of Modules

18

Module Type

18-8S

Module Configuration

8S 84P

Housing Material³

Aluminium 5251

IP Rating

IP 67

Pack Cell Count (configuration)

12096

Pack Voltage (min, nom, max)

360, 518, 605 V

Pack Voltage Derated (min, max)¹

432, 598 V

DCIR (1C, 10s, 25°C) [Ω]

0.047 [Ohms], 0.055 [Ohms], 0.063 [Ohms]

DCIR Growth at 80%. SOH
(1C, 10s, 25°C)

0.055

Short Circuit Current
(ignoring fusing, at 25°, at 100% SOH)

8400 [A], 14117 [A]

Fuse Current (Cell-Level Fusing)⁴ +/- 10%

2100 A

Fuse Current (MSD)

630 A

Specific Power

225 W/kg

Volumetric Energy Density

225 Wh/ltr

Gravimetric Energy Density

189 Wh/kg
1.
Usable range can be adjusted based on application to optimize for capacity or cycle life.
2.
Based on cell level performance but higher limits are possible with thermal management and should be discussed with Xerotech application team.
3.
Mild steel as standard unless aluminium specifically requested. Weight assumes aluminium.
4.
Assuming 1x wirebond. Can be increased by increasing number of wirebonds per cell.
Module Properties
Value

Module Type

18-8S
Cell Properties
Value

Cell Type

21700 Cylindrical EN

Thermal Management
Value

Type

Liquid Cooling (Cell Side-Wall)

Coolant

Water Ethylene Glycol (WEG) 50/50

Wetted Surfaces

Polyethylene Plastic

Max coolant pressure (gauge)

1 Bar

Nominal Coolant Inlet Temperature

20°C

Coolant Connector Type

Araymond VDA QC NW20-XA2

Coolant in Pack

2.7

Pack Environment Specifications

Parameter
Value

Discharge Temperature Range

-20°C to 60°C

Charge Temperature Range¹

0 to 45°C

Storage Temperature: 1 year
(SOC <30%, 60% Relative Humidity Max)

-20°C to 25°C

Storage Temperature: 3 months
(SOC <30%, 60% Relative Humidity Max)

-20°C to 45°C

Storage Temperature: 1 month
(SOC <30%, 60% Relative Humidity Max)

-20°C to 60°C

Humidity, Pack Operating (<25°C)

0-100%

Max Operating Altitude[m]²

9000

Min Operating Altitude [m]²

-4000

Pollution Degree

II per UL 60950

Breathable Vent

Gore PMF200542

1.
An external active thermal management system will enable the pack to operate outside of these conditions provided that the pack internals are controlled to within these temperatures.
2.
Cooling system Maximum differential pressure between internal/external must be < 1 Bar.

BDU Details

Maximum Voltage:

900 V

Maximum Current:

500 A

Electrical Specification

Parameter
Value

Type¹

Amphenol HVSL1000023a150

Max Continuous Current

500 A

Max Voltage

1,000 V

IP Rating

IP67

1.
3 pin connector as a default for maximum current handling unless 2 pin requested.

Hardware

Connection
Connection type

LV communication

TE 776163-5

Manual Service Disconnect

Amphenol PCD MSDXLM630

HV Contactors

EV200HAANA

HV Contactors

500 A

Max Continuous Current

300 A

Max Making Current

100 A

Precharge Circuit

Precharge Contactor

Panasonic HEV2aN-P-DC12V

Precharge Resistor Value¹

1k Ohm/100 Ohm

Precharge Condition

97% Link Voltage within 6 seconds

Max DC Link Capacitance

3,900 uF

1.
1kOhm is default value unless requested.
Master BMS

Isolation Monitoring

500Ω/V (Minimum 500kΩ)

Internal Datalogging

32GB SD Card

Crash Detection Method

+/- 32g (3-axis accelerometer / gyroscope)

Humidity Sensing

10% to 90% RH

Overvoltage Monitoring

Cel,, Pack and Link

Undervoltage Monitoring

Cell, Pack and Link

Overtemperature Monitoring

Module level

Undertemperature Monitoring

Module Level

Overcurrent Monitoring

Pack Primary and Secondary current shunts

HVIL

20 mA Current Source / Sink

Power Supply:

9-32V

Number of Slave BMS supported:

24

Number of cells in series for total system:

384

Range of high voltage measurement:

0 - 1,000VDC

Accuracy of high voltage measurement:

±2%

Primary Current Shunt Current Range

± 800 A

Accuracy of Primary Current Sense

±2%

Secondary Current Shunt Range

± 1,000 A

Accuracy of Secondary Current Shunt Range

±5%

Standby Consumption:

<0.02 W

Active Consumption:

<35 W Nominal, <120 W Peak

Communication interface, master-slave:

Differential pair daisy chain

Supported CAN communication type:

CAN J1939

Supported CAN speeds¹

250, 500 kbps

Number of CAN ports:

3, internal, telematics,VCU

1.
500 kbps as standard.

Enter your email below to receive the files direct to your inbox.

Enter your email below to receive the files direct to your inbox.

Enter your email below to receive the files direct to your inbox.

Enter your email below to receive the files direct to your inbox.

Enter your email below to receive the files direct to your inbox.