Hibernium® battery systems feature two high-voltage connectors, one for each polarity. Depending on the performance specification, the battery pack is equipped with two- or three-pole connectors. Please consult your specific battery datasheet for information about the type of connectors used.

Part Numbers #
Please consult your specific battery datasheet for information about the type of connectors used (3-pin/2-pin) as the mating connector is different. Select the correct tab below to see the corresponding receptacle and the suitable mating connector Part Numbers.
Systems equipped with 2-pole connectors utilize A/B coding. Please ensure correct coding match with polarity.
Do not attempt to install A-coded connector to B-coded receptacle (and vice-versa). Doing so will result in damage to the connector and receptacles.
2-pin #
Receptacle | Part number | Mating Part Number |
---|---|---|
HV + | HVSL1000022B150 | Straight – HVSL1000062B150 90° – HVSL1000082B150 |
HV – | HVSL1000022A150 | Straight – HVSL1000062A150 90° – HVSL1000082A150 |
3-pin #
Receptacle | Part number | Mating Part Number |
---|---|---|
HV + | HVSL1000023A150 | Straight – HVSL1000063A150 90° – HVSL1000083A150 |
HV – | HVSL1000023A150 | Straight – HVSL1000063A150 90° – HVSL1000083A150 |
Polarity and Connector Coding #
Please refer to the figure below to identify polarity and coding. Corresponding polarity labels are provided on the battery as well.
Top receptacle is battery pack Positive. Bottom receptacle is battery pack Negative.

Installation Steps #
1. Release the locking feature on the handle.

2. Insert the connector into the receptacle, ensuring correct A/B coding match. Ensure the lug sits properly secured in the handle groove.

3. Rotate the handle to lock the connector in place.

4. Push in the sliding lock to secure handle in position.